What is the respiratory event index (REI), and how is it different from AHI?

The respiratory event index (REI) is the number of apneas and hypopneas per hour of monitoring time on a home sleep apnea test.1,2 The apnea-hypopnea index (AHI) counts the same kinds of events per hour of total sleep time.1 Home tests typically do not monitor EEG, so REI divides by recording or monitoring time instead of sleep time.2
What is the respiratory event index?
The respiratory event index is a measure of respiratory events per unit of time on a home sleep apnea test (HSAT).3 The AASM style guide defines it as the total number of respiratory events scored, multiplied by 60 and divided by monitoring time, as defined in version 2.2 of the AASM Scoring Manual.1 The same guide states that REI should be used for home sleep apnea testing.1
The 2017 AASM guideline on diagnostic testing for adult obstructive sleep apnea (OSA) describes REI as the term used to represent the frequency of apneas and hypopneas derived from HSAT.2 REI plays the role on a home test that AHI plays on polysomnography, and the AASM severity quality measure grades both on the same scale.3
How is AHI calculated?
AHI is the number of apneas plus the number of hypopneas, multiplied by 60 and divided by total sleep time.1 The respiratory disturbance index (RDI) adds respiratory effort-related arousals to that numerator and keeps total sleep time as the denominator.1 Medicare's CPAP coverage policy describes AHI as the average number of episodes of apnea and hypopnea per hour, and RDI as the average number of respiratory disturbances per hour.4
Total sleep time depends on knowing when the patient was asleep. The AASM severity measure names AHI or RDI as the index when polysomnography is performed.3 Medicare's sleep testing policy makes a similar link for Type II monitors, describing them as devices that monitor "sleep staging, so AHI can be calculated."5 Our overview of the types of sleep studies, Type 1 to Type 4, covers those device categories.
Why do home sleep apnea tests report REI?
Home sleep apnea tests report REI because they typically do not monitor EEG, EOG and EMG, which leads to the use of recording time, rather than sleep time, as the denominator.2 The AASM style guide builds this into its definition of home sleep apnea testing, which it describes as unattended diagnostic studies to assess for OSA without the determination of sleep stage.1
The two AASM documents describe the denominator a little differently. The style guide uses monitoring time, defined as total recording time minus periods of artifact and time the patient was awake, as determined by actigraphy, body position sensor, respiratory pattern or patient diary.1 Some HSAT instructions ask patients to keep a sleep log,6 which is one way diary information can reach that calculation. How closely monitoring time approaches true sleep time depends on which of those inputs a study has.
How does the denominator change the number?
The denominator changes the number because the same event count spread over more hours gives a lower hourly rate. Illustrative example: suppose a home study scores 96 respiratory events over 8 hours of recording, and the patient slept for 6 of those hours. Dividing by 8 hours gives 12 events per hour, and dividing by the 6 hours of sleep gives 16 events per hour.
On the AASM severity ranges, 12 falls in the mild range and 16 in the moderate range.3 The event count is identical in both cases, and only the time in the calculation has changed. Wake time left in the denominator adds hours, and if no events are scored during it, the hourly index falls.
Subtracting identifiable wake periods, as the monitoring time definition does, reduces that effect.1 For that reason, it helps to know whether an HSAT result used recording time or monitoring time, and which signals defined the wake periods.
Do the same severity ranges apply?
The same severity ranges apply to AHI and REI in adults under the AASM severity quality measure.3 The measure states that severity is determined by AHI or RDI when polysomnography is performed, or by REI when out-of-center sleep testing (OCST) is performed.3
| AHI or REI (events per hour) | Classification in adults |
|---|---|
| Under 5 | Normal |
| 5 to 14.9 | Mild OSA |
| 15 to 29.9 | Moderate OSA |
| 30 or more | Severe OSA |
Because the cut points are shared and the denominators differ, the index label matters most for results near a boundary, as the illustrative example above shows. Labeling a result as REI or AHI tells the reader which denominator sits behind it. For patients, our guide on how to read sleep study results is a plain-language starting point.
What other definitions affect the number?
The hypopnea definition also changes the number. The AASM Scoring Manual recommended definition requires that changes in flow be associated with a 3% oxygen desaturation or a cortical arousal, and it allows an alternative that requires a 4% desaturation without consideration of cortical arousals.2 Depending on which definition is used, the AHI may be considerably different in a given individual.2
HSAT devices that use conventional sensors are unable to detect hypopneas associated only with cortical arousals, which the recommended rule includes.2 Our explainer on the 3% and 4% hypopnea rules covers how each rule counts events.
Medicare's CPAP coverage policy writes its criteria in AHI and RDI terms and defines a hypopnea as lasting at least 10 seconds, with at least a 30% reduction in thoracoabdominal movement or airflow compared with baseline and at least a 4% oxygen desaturation.4 When the AHI or RDI is calculated from less than 2 hours of continuous recorded sleep, the policy requires at least the number of events that would have been required in a 2-hour period.4 Medicare's sleep testing policy covers Type II and III devices used unattended in or out of a sleep lab, and Type IV devices that meet its channel criteria.5
Wesper develops FDA-cleared home sleep testing devices. Wesper Lab uses two wearable patches on the chest and abdomen to measure airflow, thoracic and abdominal effort, body position, SpO2, heart rate and sleep staging, with no nasal cannula. The Wesper portal shows multi-night and longitudinal trends, including AHI at 3% and 4% and the oxygen desaturation index (ODI), and clinicians have full access to the raw data for review. You can read more about home sleep testing for clinics on our professional page.
Frequently asked questions
Is REI the same as AHI?
The two indices count similar events but use different denominators. AHI divides by total sleep time, and REI divides by monitoring time on a home sleep apnea test.1
Why do home sleep apnea tests use REI?
Home sleep apnea tests typically do not monitor EEG, EOG and EMG, so they use recording or monitoring time instead of sleep time as the denominator.2,1
Do REI and AHI use the same severity ranges?
The AASM severity quality measure applies the same adult ranges to both indices, with moderate OSA starting at 15 events per hour.3
What is monitoring time on a home sleep apnea test?
Monitoring time is total recording time minus periods of artifact and time the patient was awake, as determined by actigraphy, body position sensor, respiratory pattern or patient diary.1
Can the hypopnea rule change the AHI?
Yes, the AASM guideline notes that the AHI may be considerably different in a given individual depending on which hypopnea definition is used.2
To see multi-night AHI and ODI trends with full access to raw data, explore home sleep testing for clinics with Wesper.
This article is for general education and is not medical advice. Talk with a licensed medical provider about your symptoms and testing options.
Sources
- American Academy of Sleep Medicine. AASM style guide for sleep medicine terminology. Updated November 2015. aasm.org
- Kapur VK, Auckley DH, Chowdhuri S, Kuhlmann DC, Mehra R, Ramar K, Harrod CG. Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of Sleep Medicine clinical practice guideline. J Clin Sleep Med. 2017;13(3):479-504. aasm.org
- American Academy of Sleep Medicine. Quality Measure #277: Sleep Apnea Severity Assessment at Initial Diagnosis. Version 9.0, December 2024. aasm.org
- Centers for Medicare & Medicaid Services. National Coverage Determination 240.4: CPAP Therapy for Obstructive Sleep Apnea (OSA). cms.gov
- Centers for Medicare & Medicaid Services. National Coverage Determination 240.4.1: Sleep Testing for Obstructive Sleep Apnea (OSA). Effective March 3, 2009. cms.gov
- American Academy of Sleep Medicine. Home Sleep Apnea Test. Sleep Education patient page, reviewed August 2020. sleepeducation.org
This article is for general information and is not medical advice. Talk to a healthcare provider about your sleep health.