Patient Uses Wesper to Evaluate Multiple Therapies for Sleep Apnea

Chelsie Rohrscheib, Ph.D. Neuroscientist and Head Sleep Expert, Wesper
Background
We present a 55-year-old man with a BMI of 26 and a history of moderate obstructive sleep apnea that is consistently affected by supine (back) sleep. He was previously diagnosed with a home sleep test and prescribed CPAP. His sleep physician would not consider alternative therapies until he tried CPAP.
Between his initial diagnosis and testing with Wesper, he lost a significant amount of weight, which resulted in a BMI reduction from 28 to 26. He expressed that he “feels like my sleep has somewhat improved since the weight loss, but I’m still having some problems.”
The patient is an engineer and described himself as “extremely data driven.” He was excited by Wesper’s ease of use and ability to collect detailed, longitudinal data. His primary use for Wesper was to track his sleep apnea after his weight loss and test several over-the-counter sleep apnea treatments before settling on CPAP therapy.
Explanation of metrics
- Apnea/Hypopnea Index (AHI): the combined average number of apneas and hypopneas that occur per hour of sleep
- Respiratory Event Index (REI): the total number of apneas and hypopneas divided by the total device (Wesper) monitoring time in hours
- Oxygen Desaturation Index (ODI): the number of times per hour of sleep that the blood oxygen level drops by a set percentage from baseline (the table below reports ODI at 3%)
Findings
The patient completed 6 tests using 4 different over-the-counter therapies that he purchased online. These therapies include an oral appliance, a positional therapy device, a tongue retention device, and a wedge pillow. After each test, he tracked his data in an Excel spreadsheet to compare results.
His first test was a baseline assessment of his sleep without the use of a therapy. His AHI was 10.8 and his supine AHI was 27, ODI was 20.3 and supine ODI was 34.6. Average SPO2 was 91%. His baseline result suggests that weight loss may have reduced his overall AHI from moderate to mild; however, he was still having significant breathing irregularities while in supine position.
Next, he tested while using a positional therapy device with the goal of preventing supine sleep. Wesper showed that the positional device was not successful at keeping him off his back, and that he spent 80 minutes sleeping in supine position. His AHI was 13.7 and supine AHI was 23.3, ODI was 15.5 and supine ODI 31. His mean SPO2 was 92%.
His third night of testing evaluated the over-the-counter appliance, a boil-and-bit design that can be adjusted to keep the lower jaw in a forward position. His AHI was 6.6 and supine AHI was 15, ODI was 8.8 and supine ODI was 15. His mean SPO2 was 92%.
His fourth night of testing evaluated a tongue retention device, which used suction to hold the tongue in place at night. His AHI was 13.4 and supine AHI was 23, ODI was 16 and supine ODI was 24.5. His mean SPO2 was 91%.
His fifth night of testing reevaluated the appliance. He described that he adjusted the device to the furthest setting and felt his teeth were not seated properly in the appliance. His AHI was 11.8 and his supine AHI was 8.3, ODI was 13.8 and supine ODI was 8.3. His mean SPO2 was 92%.
His final night of testing evaluated a wedge pillow that allowed him to sleep in supine but elevated his neck and head. His AHI was 9 and his supine AHI was 10.4, ODI was 11.4 and supine ODI was 15. His mean SPO2 was 91%.
| Supine Sleep Time | AHI (3%) | ODI (3%) | |||||||||||||||||||||||||||
| Wake Up Date | Weight [lb] | Exercise? | #Drinks | Late to Bed | Sleep Time | Coffee Time | Bed Partner | Wedge Pillow + Neck Bar | Noodle | Mouth Tape | MAD | Good Morning TRD | min | % of Total Sleep Time | Time Below 88% Sat [min] | Time Below 90% Sat [min] | All | Left | Right | Supine | Prone | All | Left | Right | Supine | Prone | Wakeups | GetUps | Avg SpO2 |
| 7/28/2023 | 173.4 | none | 1 | 12:23am | 4:58 | 93 | 31% | 13 | 44 | 10.8 | 4.6 | 2.63 | 26.95 | n/a | 20.3 | 7.22 | 5.27 | 34.66 | n/a | 10 | 2 | 91% | |||||||
| 7/29/2023 | 172.6 | none | 12:16am | 4:53 | x | 79 | 27% | 5 | 12 | 13.7 | 28.42 | 7.08 | 23.37 | n/a | 15.5 | 22.11 | 6.16 | 30.91 | n/a | 6 | 0 | 92% | |||||||
| 7/30/2023 | 172.8 | 50 mi cycle | 12:10am | 4:41 | x | 64 | 23% | 1 | 3 | 6.6 | 3.67 | 0 | 14.97 | 0 | 8.8 | 8.25 | 2.68 | 14.97 | 1.52 | 10 | 0 | 92% | |||||||
| 7/31/2023 | 172.8 | none | 12:13am | 5:04 | x | 78 | 26% | 9 | 44 | 13.4 | 4.94 | 11.39 | 23.02 | n/a | 16.2 | 8.36 | 10.51 | 24.56 | na | 6 | 3 | 91% | |||||||
| 8/1/2023 | 172 | none | 10:17pm | 5:31 | x | 86 | 26% | 0 | 7 | 11.8 | 9.75 | 3.9 | 8.32 | 15.3 | 13.8 | 12.79 | 3.42 | 8.32 | 12.75 | 10 | 1 | 92% | |||||||
| 8/2/2023 | 172.6 | none | 11:03pm | 6:28 | x | 188 | 48% | 10 | 62 | 9 | 10.03 | 4.75 | 10.48 | n/a | 11.4 | 11.28 | 5.94 | 14.92 | n/a | 8 | 1 | 91% | |||||||
On review of the results with a sleep expert, the appliance appeared to offer the most improvement, and the expert recommended that he continue testing to confirm his results. Because the wedge pillow also showed promising results, it was suggested that he might try using the wedge pillow in combination with the appliance.
Due to a large increase in AHI in supine, it was recommended that he continue to focus on eliminating supine sleep if possible with better positioning devices. The patient plans to continue testing nightly in hopes of finding an alternative to CPAP.
Conclusion
The patient completed 6 Wesper tests in a 6-day period, 1 baseline test and 5 tests while using various therapies. Comparing each night against the baseline gave him objective AHI, supine AHI and ODI data for every therapy he tried.
His tests suggested that his weight loss may have improved his sleep apnea severity, but his AHI was still elevated in supine position. Further, the data showed that the oral appliance offered the most immediate improvement, and using it in combination with positional therapy or head elevation may result in additional improvement.
While the patient acknowledges that he may not find an over-the-counter therapy that effectively treats his sleep apnea, he plans to continue home sleep testing if he starts CPAP or a prescription therapy, to track how well it works. He says that seeing the data on his over-the-counter treatments, which were not as effective as prescription therapies, makes him more willing to try CPAP.
Wesper develops FDA-cleared home sleep testing medical devices used by clinicians, and a medical provider orders the test. If you are considering a change to your sleep apnea therapy, talk with your doctor or sleep provider about home sleep testing. Clinicians can learn more on our page for providers.
This article is for general information and is not medical advice. Talk to a healthcare provider about your sleep health.